www.procontechnology.com.au
To search our website - click here.

Major credit, debit & gift cards accepted - Add 3% surcharge for AMEX and Diners

To Prices


CRO & OTHER INSTRUMENTS

Procon Technology can supply the following oscilloscopes and electronics equipment. Ideal for use in laboratories, service departments, schools and universities. Please see prices below and email us for quantity pricing and educational discounts. In Australia, call 03-98306288 now to buy!

WARNING: Some low cost Cathode Ray Oscilloscopes (CRO) have become available in Australia. We cannot recommend any of these cheap CROs because of their poor design innovation, construction quality and long-term reliability. To compare, simply check the manual (poor English), look for warning notices (they should have the maximum input voltages indicated on the front panel) and open them up (poor quality and ICs in sockets). More - click here. We are so confident of the quality of the CROs we offer that we have extended the warranty to 2 years. Schools, TAFE colleges and Universities please take note!

To monthly specials price list

QC1908 or Q0150, Protek 6502A 20MHz 2 Channel, 4 Trace CRO ... Click to enlarge

To find out more about Oscilloscopes and what they do, go to: www.doctronics.co.uk/scope.htm.

QC1908 (shown above)
The QC1908 (or Q0150) Protek (also sold under the HUNG CHANG brandname) 6502A model (6502 with ALT triggering) is a 20MHz, dual channel, four trace Cathode Ray Oscilloscope (CRO). This is a practical instrument with well thought out features including a big 6" screen for easy reading, zero parallax graticule to eliminate reading errors, TV sync separator for stable display of TV video signals and high sensitivity input amplifiers for measuring down to 1mV/div. The heavy-duty rear feet double as a power cable tidy and the versatile carry handle folds down to form a sturdy stand. The CRO is housed in a pressed steel cabinet and the control panel is clearly marked and functionally laid out. Up to 4 traces can be simultaneously displayed using the ALT-MAG and DUAL functions while advanced trig circuits ensure stable triggering even with two unrelated signals (ALT). From the large clear 6" screen to the comprehensive and well laid out controls, this CRO is as good as it looks! Comes with two quality 10:1/1:1 probes, instruction manual, spare fuses and a 2 year warranty. Highly recommended for service workbenches, design laboratories, manufacturers, schools and universities and the dedicated enthusiast. Operates on 90-130VAC or 200-250VAC 50-60Hz power through IEC socket. Also comes with CD-ROM with service and calibration manual, circuit diagrams and other useful information! i.e. How to use an oscilloscope (ideal handout for schools).

Q1536 2.7GHz Digital Frequency Counter Q1560 GW/Matrix 3MHz Function Generator & 150MHz Frequency Counter

Q1536 (shown left)
The ATTEN F2700-C is a low-cost 2.7GHz desk top digital frequency meter ideal for the repair and calibration of AM/FM radios, amateur CB radios, computer clocks and audio/video equipment. It features two channel inputs - channel 1 is 10Hz to 100MHz (input 1M ohm, max. 250VAC) and channel 2 is 100Mhz to 2.7GHz (input 50 ohm, max. 3VAC). A gate time of 0.01, 0.1 and 1 seconds is provided. An eight digit 10mm high 7 segment LEDs show the readings. It operates on 240VAC 50/60Hz. Dimensions 230x260x80mm (9x10x3") and weighs 1.8Kg (4lbs). Comes with SMA to BNC adapter (for channel 2), BNC to crocodile clips, instruction manual and 2 year warranty.

Q1560 (shown right) - 3MHz unit now available
The Matrix MFG-8216A or GW GFG-8216A is a 3MHz function or signal generator and 150MHz frequency counter. This unit is capable of providing Sine, Square, Triangular, Pulse and Sawtooth or Ramp output. The frequency range is 0.3Hz to 3MHz in 7 ranges with a 10:1 tuning control in each range. With a 50 ohm output impedance, output amplitude of 2V to 20V peak to peak (open circuit) and a DC offset adjustment of +/-10V. Also with a 20db + 20db attenuation control. A Voltage Control Function (VCF) provides a 100:1 tuning range with 0V to +10V input. A 5Hz to 150MHz frequency counter (6 digit) is incorporated for internal or external (150VAC max) measurement. Powered by 115/230VAC 50/60Hz. Dimensions 251x91x291mm (9.9x3.6x11.5") and weighs 2Kg. Comes with BNC test lead, instruction manual and 2 year warranty. For more information - click here. Also comes with CD-ROM with service and calibration manual, circuit diagrams and other useful information!

PRICE LIST.........current until 31st May, 2013AUS$+GSTNOTE
QC-1908, 20MHz Protek 6502A 2 channel 4 trace CRO...
.............+ 2 probes + 2 yr warranty! Was $799 - 5 years ago
$450.00$475.00.
Q1536, 2.7GHz desktop digital frequency counter$150.00$165.00.
Q1560, 3MHz function gen. & 150MHz freq. counter...
.............NEW unit with lower pricing! SPECIAL was $396
$270.00$297.00.
QC-1902, 60MHz 10:1/1:1 CRO probe .. suits most CROs$40.00$44.00.
QC-1903, 250MHz 100:1 CRO probe 2000V peak CAT II$60.00$66.00.
Q1190, Digital Multimeter with independent Data logging$270.00$297.00.
PCS10, Velleman 4 channel voltage USB datalogger...
..............4 x 0-30V inputs, inc. USB cable and software
$180.00$198.00pdf

Please contact us for all your test equipment needs. We source from many Australian and overseas suppliers and can provide competitive pricing. We can also supply your electronic component needs with competitive quantity pricing.

In most applications, we recommend the use of Varta alkaline batteries and the Rezap battery doctor.

Payment and delivery?
Payment may be made by debit or credit card (AMEX, DC, VISA or MASTERCARD) by PHONE, FAX or MAIL (or email at your own risk). AUS$ prices are Australian dollars. Note, these are EXPORT prices. For delivery within Australia please add 10% GST (use +GST column). For current exchange rates click here. For an order form that you can print out and fax or mail to us - click here.

Delivery charge for QC1908 within Australia $16.50 ($33 for NT, WA and remote QLD) any quantity. Delivery charge $11 for other items (any quantity). Delivery to all overseas destinations - P.O.A. (ask us). EX-GST or DUTY FREE purchases may only be made when the delivery address is outside of Australia. i.e. for EXPORT orders. Prices subject to change without notice.

Comparing CROs: If comparing the QC1908 oscilloscope with other low cost units please check the following specs; AC bandwidth (some have less on AC than DC), channel isolation, external trigger voltage maximum, AC input voltage (some have 220VAC with 250VAC maximum) and make sure it can be left on indefinitely (e.g. one had a 'Continuous Working Time' of only 8 hours). Note that the Protek 6502A provides a steady trace (i.e. alternate triggering) of both channel 1 and 2* AND provides 4 traces with two showing expanded views (x5). Check the manual - can you understand it? If you can open up the CRO and see if the ICs are in sockets (It's OK if the input amplifiers are in sockets because they could be blown up by the user). If you are carrying around the CRO any bump or knock could cause ICs to pop out of their sockets - beware! Does it have a channel 1 out? This is useful for connecting a frequency counter or other equipment. Finally, do they provide circuit diagrams, service and calibration manuals and a two year warranty?

*This 'ALT' triggering feature is very useful in servicing equipment where we often compare the signal from a known good piece of equipment with a faulty unit. Without this feature, one signal would 'wander' on the display (due to slight differences in frequency) making it difficult to compare!

More information on QC1908 or Q0150: CRT: Rectangular with integrated graticule, 1.9kV acceleration voltage and 8x10 scale. Vertical Amplifiers: (CH1 & CH2): 5mV/div to 5V/div in x 1 mode, 1mV/div to 1V/div in x 5 mode, 10-step attenuator with vernier control for variable attenuation between ranges, DC to 20 MHz bandwidth in DC mode and 10Hz to 20MHz in AC mode, AC/DC/GND input coupling. 1M ohm input impedance into 25 pF. Maximum input voltage on CH1, CH2 and Ext. trigger: 400V (DC + AC Peak) or 600V(DC + AC Peak) using x10 probes supplied. CH1 amplifier output available on rear panel 20mV/div. Z Axis: (Intensity modulation) Max input 30V (DC + AC peak), DC to 2Mhz. Display modes: Single trace, CH1 or CH2, Dual trace, chop or alternate. ADD algebraic sum of CH1 & CH2 (invert CH2 for difference), XY mode. Sweep System: Sweep speed 0.1µs to 0.2s/div ±3% in 20 steps with vernier control to provide adjustable sweep time between ranges. (1,2,5 sequence), modes A, XY, ALT.MAG, 5xMAG. Triggering: Sensitivity (INT) 3Div. (EXT). 200mV DC 2MHz & 300mV 2MHZ to 20MHz. Modes AUTO, NORM, TV-V, TV-H. Source INT, ALT, LINE, EXT, Polarity + or -, AC Coupled, DC to 20MHz. Calibration signal: 0.5V P-P square wave 1Khz. Environmental: Operating temperature 0°C to 40°C Storage temperature -10°C to +60°C. Humidity 35% to 85%. Dimensions: 140mm (H), 335mm (W) 375mm (D) Weight: approximately 7.5Kg. Power: 35W @ 200-250VAC and 90-130VAC 50-60Hz. Power lead: IEC power cord with Australian plug (i.e. any computer lead can be used).

Warning when measuring 240VAC or 415VAC: Oscilloscope manufacturers recommend extreme caution when measuring dangerous voltages. Such voltages should never be connected directly to any measuring instrument without taking appropriate precautions. It is recommended that a high voltage 100:1 probe such as the QC-1903 be used (A 100:1 probe that measures up to 5KV is also available) and that the neutral always be connected to ground or earth potential and that the earth connection on the CRO should NEVER be disconnected. i.e. be careful never to leave high voltages connected and removing the power plug (on portable devices never open the battery compartment). Always connect the earth terminal on the CRO as an additional protective measure and always use an earth leakage detector (Residual Current Device - RCD) when working around mains voltages!

Disclaimer: The above specifications are subject to change without notice. The manufacturer and Procon Technology hold no responsibility for damage expenses, lost profits, or any other claims arising from the use of these products. Please ensure the suitability of these products for your application before purchase. Colour and design may vary to that shown.